A Combination of Laboratory Testing, RCE, and Corrosion Loop for Inhibitor Selection

Autores
Bianchi, Gustavo Luis; Acosta, Verónnica Viviana; Seijas, Carlos
Año de publicación
2023
Idioma
inglés
Tipo de recurso
artículo
Estado
versión publicada
Descripción
Featured Application: Specific applications for the oil and gas industry. Testing of corrosion inhibitors to select the one with the best performance simulating field conditions. Corrosion inhibitors are evaluated in the oil industry with electrochemical tests of resistance to linear polarization with rotating cylinders following ASTM G170 and NACE 3T199 standards. With these tests, we can determine the corrosion rate (CR) and efficiency of corrosion inhibitors. In this work, a corrosion test protocol used by hydrocarbon-producing companies for the testing of corrosion inhibitors was used. This protocol consists of a 1045 carbon steel working electrode in a NACE solution composed of 9.62% NaCl, 0.45% CaCl2, 0.19% MgCl2, and 89.74% H2O, at a temperature of 65 °C and saturated with CO2. Each inhibitor tested was subjected to a series of 6000-4000-2000-4000-6000 rpm tests using rotating cylinder electrodes (RCEs). These electrochemical studies were carried out with the rotating cylinder to evaluate the ability of the inhibitor to prevent the corrosion of carbon steel in the presence of a centrifugal force. In our opinion, this test does not provide corrosion engineers with enough information to be used as a predictive tool, since what is obtained is the CR in a very short testing time. This document proposes the use of two more appropriate test methodologies, the rotating cylinder electrode (RCE) and the flow loop (FL), to evaluate the performance of the corrosion inhibitor. For the FL, the selected flow rate was 1.2 m/s, the same rate that fluids have in oil company pipelines installed in Neuquén, Argentina. Firstly, according to the company’s protocol, inhibitors are required to have an efficiency greater than or equal to 90% in RCE tests; therefore, inhibitors that meet these requirements were tested in the FL test. Unlike the RCE test, the FL test represents the experimental conditions of the laboratory that are closest to reality, for the evaluation of the performance of the inhibitors used in the pipelines of the oil and gas industry. FL tests have several problems involving corrosion, erosion, abrasion, biphasic fluids, the time it takes for the inhibitor to become effective, and the duration of its effectiveness.
Fil: Bianchi, Gustavo Luis. Universidad Nacional de La Plata. Facultad de Ingeniería. Instituto Malvinas; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata; Argentina
Fil: Acosta, Verónnica Viviana. Universidad Nacional de la Patagonia "San Juan Bosco"; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina
Fil: Seijas, Carlos. Universidad Nacional de La Plata. Facultad de Ingeniería. Instituto Malvinas; Argentina
Materia
CORROSION LOOP
RESISTANCE TO LINEAR POLARIZATION
ROTATING CYLINDER ELECTRODES
Nivel de accesibilidad
acceso abierto
Condiciones de uso
https://creativecommons.org/licenses/by/2.5/ar/
Repositorio
CONICET Digital (CONICET)
Institución
Consejo Nacional de Investigaciones Científicas y Técnicas
OAI Identificador
oai:ri.conicet.gov.ar:11336/219048

id CONICETDig_27294903b126bb45590efdff0f6bebce
oai_identifier_str oai:ri.conicet.gov.ar:11336/219048
network_acronym_str CONICETDig
repository_id_str 3498
network_name_str CONICET Digital (CONICET)
spelling A Combination of Laboratory Testing, RCE, and Corrosion Loop for Inhibitor SelectionBianchi, Gustavo LuisAcosta, Verónnica VivianaSeijas, CarlosCORROSION LOOPRESISTANCE TO LINEAR POLARIZATIONROTATING CYLINDER ELECTRODEShttps://purl.org/becyt/ford/2.5https://purl.org/becyt/ford/2Featured Application: Specific applications for the oil and gas industry. Testing of corrosion inhibitors to select the one with the best performance simulating field conditions. Corrosion inhibitors are evaluated in the oil industry with electrochemical tests of resistance to linear polarization with rotating cylinders following ASTM G170 and NACE 3T199 standards. With these tests, we can determine the corrosion rate (CR) and efficiency of corrosion inhibitors. In this work, a corrosion test protocol used by hydrocarbon-producing companies for the testing of corrosion inhibitors was used. This protocol consists of a 1045 carbon steel working electrode in a NACE solution composed of 9.62% NaCl, 0.45% CaCl2, 0.19% MgCl2, and 89.74% H2O, at a temperature of 65 °C and saturated with CO2. Each inhibitor tested was subjected to a series of 6000-4000-2000-4000-6000 rpm tests using rotating cylinder electrodes (RCEs). These electrochemical studies were carried out with the rotating cylinder to evaluate the ability of the inhibitor to prevent the corrosion of carbon steel in the presence of a centrifugal force. In our opinion, this test does not provide corrosion engineers with enough information to be used as a predictive tool, since what is obtained is the CR in a very short testing time. This document proposes the use of two more appropriate test methodologies, the rotating cylinder electrode (RCE) and the flow loop (FL), to evaluate the performance of the corrosion inhibitor. For the FL, the selected flow rate was 1.2 m/s, the same rate that fluids have in oil company pipelines installed in Neuquén, Argentina. Firstly, according to the company’s protocol, inhibitors are required to have an efficiency greater than or equal to 90% in RCE tests; therefore, inhibitors that meet these requirements were tested in the FL test. Unlike the RCE test, the FL test represents the experimental conditions of the laboratory that are closest to reality, for the evaluation of the performance of the inhibitors used in the pipelines of the oil and gas industry. FL tests have several problems involving corrosion, erosion, abrasion, biphasic fluids, the time it takes for the inhibitor to become effective, and the duration of its effectiveness.Fil: Bianchi, Gustavo Luis. Universidad Nacional de La Plata. Facultad de Ingeniería. Instituto Malvinas; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata; ArgentinaFil: Acosta, Verónnica Viviana. Universidad Nacional de la Patagonia "San Juan Bosco"; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; ArgentinaFil: Seijas, Carlos. Universidad Nacional de La Plata. Facultad de Ingeniería. Instituto Malvinas; ArgentinaMultidisciplinary Digital Publishing Institute2023-04info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/219048Bianchi, Gustavo Luis; Acosta, Verónnica Viviana; Seijas, Carlos; A Combination of Laboratory Testing, RCE, and Corrosion Loop for Inhibitor Selection; Multidisciplinary Digital Publishing Institute; Applied Sciences; 13; 7; 4-2023; 1-122076-3417CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/url/https://www.mdpi.com/2076-3417/13/7/4586info:eu-repo/semantics/altIdentifier/doi/10.3390/app13074586info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2026-08-25T14:39:50Zoai:ri.conicet.gov.ar:11336/219048instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982026-08-25 14:39:50.501CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse
dc.title.none.fl_str_mv A Combination of Laboratory Testing, RCE, and Corrosion Loop for Inhibitor Selection
title A Combination of Laboratory Testing, RCE, and Corrosion Loop for Inhibitor Selection
spellingShingle A Combination of Laboratory Testing, RCE, and Corrosion Loop for Inhibitor Selection
Bianchi, Gustavo Luis
CORROSION LOOP
RESISTANCE TO LINEAR POLARIZATION
ROTATING CYLINDER ELECTRODES
title_short A Combination of Laboratory Testing, RCE, and Corrosion Loop for Inhibitor Selection
title_full A Combination of Laboratory Testing, RCE, and Corrosion Loop for Inhibitor Selection
title_fullStr A Combination of Laboratory Testing, RCE, and Corrosion Loop for Inhibitor Selection
title_full_unstemmed A Combination of Laboratory Testing, RCE, and Corrosion Loop for Inhibitor Selection
title_sort A Combination of Laboratory Testing, RCE, and Corrosion Loop for Inhibitor Selection
dc.creator.none.fl_str_mv Bianchi, Gustavo Luis
Acosta, Verónnica Viviana
Seijas, Carlos
author Bianchi, Gustavo Luis
author_facet Bianchi, Gustavo Luis
Acosta, Verónnica Viviana
Seijas, Carlos
author_role author
author2 Acosta, Verónnica Viviana
Seijas, Carlos
author2_role author
author
dc.subject.none.fl_str_mv CORROSION LOOP
RESISTANCE TO LINEAR POLARIZATION
ROTATING CYLINDER ELECTRODES
topic CORROSION LOOP
RESISTANCE TO LINEAR POLARIZATION
ROTATING CYLINDER ELECTRODES
purl_subject.fl_str_mv https://purl.org/becyt/ford/2.5
https://purl.org/becyt/ford/2
dc.description.none.fl_txt_mv Featured Application: Specific applications for the oil and gas industry. Testing of corrosion inhibitors to select the one with the best performance simulating field conditions. Corrosion inhibitors are evaluated in the oil industry with electrochemical tests of resistance to linear polarization with rotating cylinders following ASTM G170 and NACE 3T199 standards. With these tests, we can determine the corrosion rate (CR) and efficiency of corrosion inhibitors. In this work, a corrosion test protocol used by hydrocarbon-producing companies for the testing of corrosion inhibitors was used. This protocol consists of a 1045 carbon steel working electrode in a NACE solution composed of 9.62% NaCl, 0.45% CaCl2, 0.19% MgCl2, and 89.74% H2O, at a temperature of 65 °C and saturated with CO2. Each inhibitor tested was subjected to a series of 6000-4000-2000-4000-6000 rpm tests using rotating cylinder electrodes (RCEs). These electrochemical studies were carried out with the rotating cylinder to evaluate the ability of the inhibitor to prevent the corrosion of carbon steel in the presence of a centrifugal force. In our opinion, this test does not provide corrosion engineers with enough information to be used as a predictive tool, since what is obtained is the CR in a very short testing time. This document proposes the use of two more appropriate test methodologies, the rotating cylinder electrode (RCE) and the flow loop (FL), to evaluate the performance of the corrosion inhibitor. For the FL, the selected flow rate was 1.2 m/s, the same rate that fluids have in oil company pipelines installed in Neuquén, Argentina. Firstly, according to the company’s protocol, inhibitors are required to have an efficiency greater than or equal to 90% in RCE tests; therefore, inhibitors that meet these requirements were tested in the FL test. Unlike the RCE test, the FL test represents the experimental conditions of the laboratory that are closest to reality, for the evaluation of the performance of the inhibitors used in the pipelines of the oil and gas industry. FL tests have several problems involving corrosion, erosion, abrasion, biphasic fluids, the time it takes for the inhibitor to become effective, and the duration of its effectiveness.
Fil: Bianchi, Gustavo Luis. Universidad Nacional de La Plata. Facultad de Ingeniería. Instituto Malvinas; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata; Argentina
Fil: Acosta, Verónnica Viviana. Universidad Nacional de la Patagonia "San Juan Bosco"; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina
Fil: Seijas, Carlos. Universidad Nacional de La Plata. Facultad de Ingeniería. Instituto Malvinas; Argentina
description Featured Application: Specific applications for the oil and gas industry. Testing of corrosion inhibitors to select the one with the best performance simulating field conditions. Corrosion inhibitors are evaluated in the oil industry with electrochemical tests of resistance to linear polarization with rotating cylinders following ASTM G170 and NACE 3T199 standards. With these tests, we can determine the corrosion rate (CR) and efficiency of corrosion inhibitors. In this work, a corrosion test protocol used by hydrocarbon-producing companies for the testing of corrosion inhibitors was used. This protocol consists of a 1045 carbon steel working electrode in a NACE solution composed of 9.62% NaCl, 0.45% CaCl2, 0.19% MgCl2, and 89.74% H2O, at a temperature of 65 °C and saturated with CO2. Each inhibitor tested was subjected to a series of 6000-4000-2000-4000-6000 rpm tests using rotating cylinder electrodes (RCEs). These electrochemical studies were carried out with the rotating cylinder to evaluate the ability of the inhibitor to prevent the corrosion of carbon steel in the presence of a centrifugal force. In our opinion, this test does not provide corrosion engineers with enough information to be used as a predictive tool, since what is obtained is the CR in a very short testing time. This document proposes the use of two more appropriate test methodologies, the rotating cylinder electrode (RCE) and the flow loop (FL), to evaluate the performance of the corrosion inhibitor. For the FL, the selected flow rate was 1.2 m/s, the same rate that fluids have in oil company pipelines installed in Neuquén, Argentina. Firstly, according to the company’s protocol, inhibitors are required to have an efficiency greater than or equal to 90% in RCE tests; therefore, inhibitors that meet these requirements were tested in the FL test. Unlike the RCE test, the FL test represents the experimental conditions of the laboratory that are closest to reality, for the evaluation of the performance of the inhibitors used in the pipelines of the oil and gas industry. FL tests have several problems involving corrosion, erosion, abrasion, biphasic fluids, the time it takes for the inhibitor to become effective, and the duration of its effectiveness.
publishDate 2023
dc.date.none.fl_str_mv 2023-04
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
http://purl.org/coar/resource_type/c_6501
info:ar-repo/semantics/articulo
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://hdl.handle.net/11336/219048
Bianchi, Gustavo Luis; Acosta, Verónnica Viviana; Seijas, Carlos; A Combination of Laboratory Testing, RCE, and Corrosion Loop for Inhibitor Selection; Multidisciplinary Digital Publishing Institute; Applied Sciences; 13; 7; 4-2023; 1-12
2076-3417
CONICET Digital
CONICET
url http://hdl.handle.net/11336/219048
identifier_str_mv Bianchi, Gustavo Luis; Acosta, Verónnica Viviana; Seijas, Carlos; A Combination of Laboratory Testing, RCE, and Corrosion Loop for Inhibitor Selection; Multidisciplinary Digital Publishing Institute; Applied Sciences; 13; 7; 4-2023; 1-12
2076-3417
CONICET Digital
CONICET
dc.language.none.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv info:eu-repo/semantics/altIdentifier/url/https://www.mdpi.com/2076-3417/13/7/4586
info:eu-repo/semantics/altIdentifier/doi/10.3390/app13074586
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
https://creativecommons.org/licenses/by/2.5/ar/
eu_rights_str_mv openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by/2.5/ar/
dc.format.none.fl_str_mv application/pdf
application/pdf
dc.publisher.none.fl_str_mv Multidisciplinary Digital Publishing Institute
publisher.none.fl_str_mv Multidisciplinary Digital Publishing Institute
dc.source.none.fl_str_mv reponame:CONICET Digital (CONICET)
instname:Consejo Nacional de Investigaciones Científicas y Técnicas
reponame_str CONICET Digital (CONICET)
collection CONICET Digital (CONICET)
instname_str Consejo Nacional de Investigaciones Científicas y Técnicas
repository.name.fl_str_mv CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas
repository.mail.fl_str_mv dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar
_version_ 1874774413176471552
score 13.334379