High-quality nodule analysis in spheroidal graphite cast iron using X-ray micro-computed tomography.
- Autores
- Díaz, Felipe; Peralta, Matías; Toledo, J.C,; Fernandino, D. O.
- Año de publicación
- 2022
- Idioma
- inglés
- Tipo de recurso
- artículo
- Estado
- versión publicada
- Descripción
- This work is a continuation of the studies presented in a recent paper by the authors, where a methodology to obtain different nodule quality categories in spheroidal graphite cast iron, was proposed. In this study, an exhaustive analysis of the highest-quality graphite nodules was performed. The experimental methodology involves X-ray micro-computed tomography analysis and digital image post-processing of the high-quality graphite nodule population. Furthermore, different subpopulations were selected, following a nodular size criterion. The procedure involves the evaluation and comparison of the sphericity and compactness distributions and the distances between neighbouring nodules by using ad-hoc image processing software. The results reveal the complementary nature of the sphericity and compactness parameters, which allow classifying, with great accuracy, different nodular quality categories of spheroidal graphite cast iron. Additionally, new viewpoints about the nodular morphology study and the distribution of quality nodules in the metallic matrix were provided, which could be extended to other heterogeneous materials.
Fil: Toledo, J.C. Universidad Tecnológica Nacional. Facultad Regional Rafaela; Argentina.
Fil: Díaz, F. V. Universidad Tecnológica Nacional. Facultad Regional Rafaela; Argentina.
Fil: Peralta. M. E. Departamento de Validación de Equipos y Componentes, Instituto Nacional de Tecnología Industrial-Centro Litoral; Argentina
Fil: Fernandino, D. O. INTEMA, Universidad Nacional de Mar del Plata-CONICET; Argentina.
Peer Reviewed - Fuente
- J.C. Toledo et alii, Frattura ed Integrità Strutturale, 62 (2022) 279-288
- Materia
-
X-ray
micro-tomography
Sphericity
Compactness
Nondestructive analysis
Spheroidal graphite cast iron - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- 2024-06-07T19:11:14Z
- Repositorio
.jpg)
- Institución
- Universidad Tecnológica Nacional
- OAI Identificador
- oai:ria.utn.edu.ar:20.500.12272/10937
Ver los metadatos del registro completo
| id |
RIAUTN_b902f2e2ad7ca98aaba476b58ce9c1c5 |
|---|---|
| oai_identifier_str |
oai:ria.utn.edu.ar:20.500.12272/10937 |
| network_acronym_str |
RIAUTN |
| repository_id_str |
a |
| network_name_str |
Repositorio Institucional Abierto (UTN) |
| spelling |
High-quality nodule analysis in spheroidal graphite cast iron using X-ray micro-computed tomography.Díaz, FelipePeralta, MatíasToledo, J.C,Fernandino, D. O.X-raymicro-tomographySphericityCompactnessNondestructive analysisSpheroidal graphite cast ironThis work is a continuation of the studies presented in a recent paper by the authors, where a methodology to obtain different nodule quality categories in spheroidal graphite cast iron, was proposed. In this study, an exhaustive analysis of the highest-quality graphite nodules was performed. The experimental methodology involves X-ray micro-computed tomography analysis and digital image post-processing of the high-quality graphite nodule population. Furthermore, different subpopulations were selected, following a nodular size criterion. The procedure involves the evaluation and comparison of the sphericity and compactness distributions and the distances between neighbouring nodules by using ad-hoc image processing software. The results reveal the complementary nature of the sphericity and compactness parameters, which allow classifying, with great accuracy, different nodular quality categories of spheroidal graphite cast iron. Additionally, new viewpoints about the nodular morphology study and the distribution of quality nodules in the metallic matrix were provided, which could be extended to other heterogeneous materials.Fil: Toledo, J.C. Universidad Tecnológica Nacional. Facultad Regional Rafaela; Argentina.Fil: Díaz, F. V. Universidad Tecnológica Nacional. Facultad Regional Rafaela; Argentina.Fil: Peralta. M. E. Departamento de Validación de Equipos y Componentes, Instituto Nacional de Tecnología Industrial-Centro Litoral; ArgentinaFil: Fernandino, D. O. INTEMA, Universidad Nacional de Mar del Plata-CONICET; Argentina.Peer Reviewed2024-06-07T19:11:14Z2024-06-07T19:11:14Z2022info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articulopdfapplication/pdfhttp://hdl.handle.net/20.500.12272/1093710.3221J.C. Toledo et alii, Frattura ed Integrità Strutturale, 62 (2022) 279-288reponame:Repositorio Institucional Abierto (UTN)instname:Universidad Tecnológica Nacionalenginfo:eu-repo/semantics/openAccess2024-06-07T19:11:14Zhttp://creativecommons.org/licenses/by-nc-sa/4.0/Atribución-NoComercial-CompartirIgual 4.0 InternacionalSe autoriza la reproducción para fines educativos, culturales y académicos con la debida mención de la fuente.2026-09-24T12:48:47Zoai:ria.utn.edu.ar:20.500.12272/10937instacron:UTNInstitucionalhttp://ria.utn.edu.ar/Universidad públicaNo correspondehttp://ria.utn.edu.ar/oaigestionria@rec.utn.edu.ar; fsuarez@rec.utn.edu.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:a2026-09-24 12:48:48.47Repositorio Institucional Abierto (UTN) - Universidad Tecnológica Nacionalfalse |
| dc.title.none.fl_str_mv |
High-quality nodule analysis in spheroidal graphite cast iron using X-ray micro-computed tomography. |
| title |
High-quality nodule analysis in spheroidal graphite cast iron using X-ray micro-computed tomography. |
| spellingShingle |
High-quality nodule analysis in spheroidal graphite cast iron using X-ray micro-computed tomography. Díaz, Felipe X-ray micro-tomography Sphericity Compactness Nondestructive analysis Spheroidal graphite cast iron |
| title_short |
High-quality nodule analysis in spheroidal graphite cast iron using X-ray micro-computed tomography. |
| title_full |
High-quality nodule analysis in spheroidal graphite cast iron using X-ray micro-computed tomography. |
| title_fullStr |
High-quality nodule analysis in spheroidal graphite cast iron using X-ray micro-computed tomography. |
| title_full_unstemmed |
High-quality nodule analysis in spheroidal graphite cast iron using X-ray micro-computed tomography. |
| title_sort |
High-quality nodule analysis in spheroidal graphite cast iron using X-ray micro-computed tomography. |
| dc.creator.none.fl_str_mv |
Díaz, Felipe Peralta, Matías Toledo, J.C, Fernandino, D. O. |
| author |
Díaz, Felipe |
| author_facet |
Díaz, Felipe Peralta, Matías Toledo, J.C, Fernandino, D. O. |
| author_role |
author |
| author2 |
Peralta, Matías Toledo, J.C, Fernandino, D. O. |
| author2_role |
author author author |
| dc.subject.none.fl_str_mv |
X-ray micro-tomography Sphericity Compactness Nondestructive analysis Spheroidal graphite cast iron |
| topic |
X-ray micro-tomography Sphericity Compactness Nondestructive analysis Spheroidal graphite cast iron |
| dc.description.none.fl_txt_mv |
This work is a continuation of the studies presented in a recent paper by the authors, where a methodology to obtain different nodule quality categories in spheroidal graphite cast iron, was proposed. In this study, an exhaustive analysis of the highest-quality graphite nodules was performed. The experimental methodology involves X-ray micro-computed tomography analysis and digital image post-processing of the high-quality graphite nodule population. Furthermore, different subpopulations were selected, following a nodular size criterion. The procedure involves the evaluation and comparison of the sphericity and compactness distributions and the distances between neighbouring nodules by using ad-hoc image processing software. The results reveal the complementary nature of the sphericity and compactness parameters, which allow classifying, with great accuracy, different nodular quality categories of spheroidal graphite cast iron. Additionally, new viewpoints about the nodular morphology study and the distribution of quality nodules in the metallic matrix were provided, which could be extended to other heterogeneous materials. Fil: Toledo, J.C. Universidad Tecnológica Nacional. Facultad Regional Rafaela; Argentina. Fil: Díaz, F. V. Universidad Tecnológica Nacional. Facultad Regional Rafaela; Argentina. Fil: Peralta. M. E. Departamento de Validación de Equipos y Componentes, Instituto Nacional de Tecnología Industrial-Centro Litoral; Argentina Fil: Fernandino, D. O. INTEMA, Universidad Nacional de Mar del Plata-CONICET; Argentina. Peer Reviewed |
| description |
This work is a continuation of the studies presented in a recent paper by the authors, where a methodology to obtain different nodule quality categories in spheroidal graphite cast iron, was proposed. In this study, an exhaustive analysis of the highest-quality graphite nodules was performed. The experimental methodology involves X-ray micro-computed tomography analysis and digital image post-processing of the high-quality graphite nodule population. Furthermore, different subpopulations were selected, following a nodular size criterion. The procedure involves the evaluation and comparison of the sphericity and compactness distributions and the distances between neighbouring nodules by using ad-hoc image processing software. The results reveal the complementary nature of the sphericity and compactness parameters, which allow classifying, with great accuracy, different nodular quality categories of spheroidal graphite cast iron. Additionally, new viewpoints about the nodular morphology study and the distribution of quality nodules in the metallic matrix were provided, which could be extended to other heterogeneous materials. |
| publishDate |
2022 |
| dc.date.none.fl_str_mv |
2022 2024-06-07T19:11:14Z 2024-06-07T19:11:14Z |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.none.fl_str_mv |
http://hdl.handle.net/20.500.12272/10937 10.3221 |
| url |
http://hdl.handle.net/20.500.12272/10937 |
| identifier_str_mv |
10.3221 |
| dc.language.none.fl_str_mv |
eng |
| language |
eng |
| dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess 2024-06-07T19:11:14Z http://creativecommons.org/licenses/by-nc-sa/4.0/ Atribución-NoComercial-CompartirIgual 4.0 Internacional Se autoriza la reproducción para fines educativos, culturales y académicos con la debida mención de la fuente. |
| eu_rights_str_mv |
openAccess |
| rights_invalid_str_mv |
2024-06-07T19:11:14Z http://creativecommons.org/licenses/by-nc-sa/4.0/ Atribución-NoComercial-CompartirIgual 4.0 Internacional Se autoriza la reproducción para fines educativos, culturales y académicos con la debida mención de la fuente. |
| dc.format.none.fl_str_mv |
pdf application/pdf |
| dc.source.none.fl_str_mv |
J.C. Toledo et alii, Frattura ed Integrità Strutturale, 62 (2022) 279-288 reponame:Repositorio Institucional Abierto (UTN) instname:Universidad Tecnológica Nacional |
| reponame_str |
Repositorio Institucional Abierto (UTN) |
| collection |
Repositorio Institucional Abierto (UTN) |
| instname_str |
Universidad Tecnológica Nacional |
| repository.name.fl_str_mv |
Repositorio Institucional Abierto (UTN) - Universidad Tecnológica Nacional |
| repository.mail.fl_str_mv |
gestionria@rec.utn.edu.ar; fsuarez@rec.utn.edu.ar |
| _version_ |
1877230976560529408 |
| score |
13.265058 |