Comparison of removal efficiency of pathogenic microbes in four types of wastewater treatment systems in Denmark
- Autores
- Adrados, B.; Arias, C. A.; Pérez, Leonardo Martín; Codony, F.; Bécares, E.; Brix, H.; Morató Farreras, Jordi
- Año de publicación
- 2018
- Idioma
- inglés
- Tipo de recurso
- artículo
- Estado
- versión aceptada
- Descripción
- Fil: Adrados, B. Universitat Politècnica de Catalunya. Health and Environmental Microbiology Laboratory; España
Fil: Adrados, B. Unesco Chair on Sustainability; España
Fil: Arias, C. A. Aarhus University. Department of Bioscience. Dinamarca
Fil: Pérez, Leonardo Martín. Pontificia Universidad Católica Argentina. Facultad de Química e Ingeniería de Rosario. Departamento de Investigación Institucional; Argentina
Fil: Pérez, Leonardo Martín. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina
Fil: Pérez, Leonardo Martín. Universitat Politècnica de Catalunya. Health and Environmental Microbiology Laboratory; España
Fil: Pérez, Leonardo Martín. Unesco Chair on Sustainability; España
Fil: Codony, F. Laboratori Municipal de Mataró; España
Fil: Bécares, E. University of León. Faculty of Environmental and Biological Sciences. Department of Biodiversity and Environmental Management; España
Fil: Brix, H. Aarhus University. Department of Bioscience. Dinamarca
Fil: Morató, J. Universitat Politècnica de Catalunya. Health and Environmental Microbiology Laboratory; España
Fil: Morató, J. Unesco Chair on Sustainability; España
Abstract: The aim of the present work was to evaluate and compare the performance in the removal of pathogenic microbes in four different types of decentralized wastewater treatment systems, namely: horizontal flow constructed wetlands (HFCW), vertical flow constructed wetlands (VFCW), biological sand filters (BSF) and biofilters (BF). All the systems analyzed are located in Jutland, Denmark. Water sampling took place during a three months period that covered from winter to spring. Conventional microbial indicators such as Escherichia coli, total coliforms (TC), intestinal enterococci and sulphite-reducing clostridia were quantified using traditional microbiological culture methods, whereas Bacteroides spp. determination was performed by quantitative PCR (qPCR). Other water quality parameters such as dissolved oxygen, biological oxygen demand (BOD5), total suspended solids (TSS), pH, temperature, ammonium concentration and conductivity of influent and effluent water samples were also analyzed. The results showed that bacterial indicators significantly reduced in all the systems analyzed. In general, BF showed the best performance in the removal of microbes for all bacteria studied, while BSF demonstrated an improved capacity to eliminate E. coli and TC. Contrarily, VFCW seems to be more effective reducing the amount of intestinal enterococci, sulphite-reducing clostridia, and Bacteroides spp. In the present study, HFCW were the less efficient wastewater treatment system for the elimination of the evaluated pathogens. However, the performance in the removal of microbes was still significant considering that such systems were the oldest under operation (with over 20 years of continuous task). - Fuente
- Ecological Engineering. 2018, 124
- Materia
-
TRATAMIENTO DE AGUAS RESIDUALES
INGENIERIA SANITARIA
ANALISIS DEL AGUA - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- https://creativecommons.org/licenses/by-nc-sa/4.0/
- Repositorio
.jpg)
- Institución
- Pontificia Universidad Católica Argentina
- OAI Identificador
- oai:ucacris:123456789/9529
Ver los metadatos del registro completo
| id |
RIUCA_63c76f7d13d52f9a40e9aa245debfd4d |
|---|---|
| oai_identifier_str |
oai:ucacris:123456789/9529 |
| network_acronym_str |
RIUCA |
| repository_id_str |
2585 |
| network_name_str |
Repositorio Institucional (UCA) |
| spelling |
Comparison of removal efficiency of pathogenic microbes in four types of wastewater treatment systems in DenmarkAdrados, B.Arias, C. A.Pérez, Leonardo MartínCodony, F.Bécares, E.Brix, H.Morató Farreras, JordiTRATAMIENTO DE AGUAS RESIDUALESINGENIERIA SANITARIAANALISIS DEL AGUAFil: Adrados, B. Universitat Politècnica de Catalunya. Health and Environmental Microbiology Laboratory; EspañaFil: Adrados, B. Unesco Chair on Sustainability; EspañaFil: Arias, C. A. Aarhus University. Department of Bioscience. DinamarcaFil: Pérez, Leonardo Martín. Pontificia Universidad Católica Argentina. Facultad de Química e Ingeniería de Rosario. Departamento de Investigación Institucional; ArgentinaFil: Pérez, Leonardo Martín. Consejo Nacional de Investigaciones Científicas y Técnicas; ArgentinaFil: Pérez, Leonardo Martín. Universitat Politècnica de Catalunya. Health and Environmental Microbiology Laboratory; EspañaFil: Pérez, Leonardo Martín. Unesco Chair on Sustainability; EspañaFil: Codony, F. Laboratori Municipal de Mataró; EspañaFil: Bécares, E. University of León. Faculty of Environmental and Biological Sciences. Department of Biodiversity and Environmental Management; EspañaFil: Brix, H. Aarhus University. Department of Bioscience. DinamarcaFil: Morató, J. Universitat Politècnica de Catalunya. Health and Environmental Microbiology Laboratory; EspañaFil: Morató, J. Unesco Chair on Sustainability; EspañaAbstract: The aim of the present work was to evaluate and compare the performance in the removal of pathogenic microbes in four different types of decentralized wastewater treatment systems, namely: horizontal flow constructed wetlands (HFCW), vertical flow constructed wetlands (VFCW), biological sand filters (BSF) and biofilters (BF). All the systems analyzed are located in Jutland, Denmark. Water sampling took place during a three months period that covered from winter to spring. Conventional microbial indicators such as Escherichia coli, total coliforms (TC), intestinal enterococci and sulphite-reducing clostridia were quantified using traditional microbiological culture methods, whereas Bacteroides spp. determination was performed by quantitative PCR (qPCR). Other water quality parameters such as dissolved oxygen, biological oxygen demand (BOD5), total suspended solids (TSS), pH, temperature, ammonium concentration and conductivity of influent and effluent water samples were also analyzed. The results showed that bacterial indicators significantly reduced in all the systems analyzed. In general, BF showed the best performance in the removal of microbes for all bacteria studied, while BSF demonstrated an improved capacity to eliminate E. coli and TC. Contrarily, VFCW seems to be more effective reducing the amount of intestinal enterococci, sulphite-reducing clostridia, and Bacteroides spp. In the present study, HFCW were the less efficient wastewater treatment system for the elimination of the evaluated pathogens. However, the performance in the removal of microbes was still significant considering that such systems were the oldest under operation (with over 20 years of continuous task).Elsevier2018info:eu-repo/semantics/articleinfo:eu-repo/semantics/acceptedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfhttps://repositorio.uca.edu.ar/handle/123456789/95290925-857410.1016/j.ecoleng.2018.09.013Adrados, B. et al. Comparison of removal efficiency of pathogenic microbes in four types of wastewater treatment systems in Denmark [en línea]. Ecological Engineering. 2018, 124. doi:10.1016/j.ecoleng.2018.09.013 Disponible en: https://repositorio.uca.edu.ar/handle/123456789/9529Ecological Engineering. 2018, 124reponame:Repositorio Institucional (UCA)instname:Pontificia Universidad Católica Argentinaenginfo:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/4.0/2026-09-28T11:06:41Zoai:ucacris:123456789/9529instacron:UCAInstitucionalhttps://repositorio.uca.edu.ar/Universidad privadaNo correspondehttps://repositorio.uca.edu.ar/oaiclaudia_fernandez@uca.edu.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:25852026-09-28 11:06:42.127Repositorio Institucional (UCA) - Pontificia Universidad Católica Argentinafalse |
| dc.title.none.fl_str_mv |
Comparison of removal efficiency of pathogenic microbes in four types of wastewater treatment systems in Denmark |
| title |
Comparison of removal efficiency of pathogenic microbes in four types of wastewater treatment systems in Denmark |
| spellingShingle |
Comparison of removal efficiency of pathogenic microbes in four types of wastewater treatment systems in Denmark Adrados, B. TRATAMIENTO DE AGUAS RESIDUALES INGENIERIA SANITARIA ANALISIS DEL AGUA |
| title_short |
Comparison of removal efficiency of pathogenic microbes in four types of wastewater treatment systems in Denmark |
| title_full |
Comparison of removal efficiency of pathogenic microbes in four types of wastewater treatment systems in Denmark |
| title_fullStr |
Comparison of removal efficiency of pathogenic microbes in four types of wastewater treatment systems in Denmark |
| title_full_unstemmed |
Comparison of removal efficiency of pathogenic microbes in four types of wastewater treatment systems in Denmark |
| title_sort |
Comparison of removal efficiency of pathogenic microbes in four types of wastewater treatment systems in Denmark |
| dc.creator.none.fl_str_mv |
Adrados, B. Arias, C. A. Pérez, Leonardo Martín Codony, F. Bécares, E. Brix, H. Morató Farreras, Jordi |
| author |
Adrados, B. |
| author_facet |
Adrados, B. Arias, C. A. Pérez, Leonardo Martín Codony, F. Bécares, E. Brix, H. Morató Farreras, Jordi |
| author_role |
author |
| author2 |
Arias, C. A. Pérez, Leonardo Martín Codony, F. Bécares, E. Brix, H. Morató Farreras, Jordi |
| author2_role |
author author author author author author |
| dc.subject.none.fl_str_mv |
TRATAMIENTO DE AGUAS RESIDUALES INGENIERIA SANITARIA ANALISIS DEL AGUA |
| topic |
TRATAMIENTO DE AGUAS RESIDUALES INGENIERIA SANITARIA ANALISIS DEL AGUA |
| dc.description.none.fl_txt_mv |
Fil: Adrados, B. Universitat Politècnica de Catalunya. Health and Environmental Microbiology Laboratory; España Fil: Adrados, B. Unesco Chair on Sustainability; España Fil: Arias, C. A. Aarhus University. Department of Bioscience. Dinamarca Fil: Pérez, Leonardo Martín. Pontificia Universidad Católica Argentina. Facultad de Química e Ingeniería de Rosario. Departamento de Investigación Institucional; Argentina Fil: Pérez, Leonardo Martín. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina Fil: Pérez, Leonardo Martín. Universitat Politècnica de Catalunya. Health and Environmental Microbiology Laboratory; España Fil: Pérez, Leonardo Martín. Unesco Chair on Sustainability; España Fil: Codony, F. Laboratori Municipal de Mataró; España Fil: Bécares, E. University of León. Faculty of Environmental and Biological Sciences. Department of Biodiversity and Environmental Management; España Fil: Brix, H. Aarhus University. Department of Bioscience. Dinamarca Fil: Morató, J. Universitat Politècnica de Catalunya. Health and Environmental Microbiology Laboratory; España Fil: Morató, J. Unesco Chair on Sustainability; España Abstract: The aim of the present work was to evaluate and compare the performance in the removal of pathogenic microbes in four different types of decentralized wastewater treatment systems, namely: horizontal flow constructed wetlands (HFCW), vertical flow constructed wetlands (VFCW), biological sand filters (BSF) and biofilters (BF). All the systems analyzed are located in Jutland, Denmark. Water sampling took place during a three months period that covered from winter to spring. Conventional microbial indicators such as Escherichia coli, total coliforms (TC), intestinal enterococci and sulphite-reducing clostridia were quantified using traditional microbiological culture methods, whereas Bacteroides spp. determination was performed by quantitative PCR (qPCR). Other water quality parameters such as dissolved oxygen, biological oxygen demand (BOD5), total suspended solids (TSS), pH, temperature, ammonium concentration and conductivity of influent and effluent water samples were also analyzed. The results showed that bacterial indicators significantly reduced in all the systems analyzed. In general, BF showed the best performance in the removal of microbes for all bacteria studied, while BSF demonstrated an improved capacity to eliminate E. coli and TC. Contrarily, VFCW seems to be more effective reducing the amount of intestinal enterococci, sulphite-reducing clostridia, and Bacteroides spp. In the present study, HFCW were the less efficient wastewater treatment system for the elimination of the evaluated pathogens. However, the performance in the removal of microbes was still significant considering that such systems were the oldest under operation (with over 20 years of continuous task). |
| description |
Fil: Adrados, B. Universitat Politècnica de Catalunya. Health and Environmental Microbiology Laboratory; España |
| publishDate |
2018 |
| dc.date.none.fl_str_mv |
2018 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/acceptedVersion http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
| format |
article |
| status_str |
acceptedVersion |
| dc.identifier.none.fl_str_mv |
https://repositorio.uca.edu.ar/handle/123456789/9529 0925-8574 10.1016/j.ecoleng.2018.09.013 Adrados, B. et al. Comparison of removal efficiency of pathogenic microbes in four types of wastewater treatment systems in Denmark [en línea]. Ecological Engineering. 2018, 124. doi:10.1016/j.ecoleng.2018.09.013 Disponible en: https://repositorio.uca.edu.ar/handle/123456789/9529 |
| url |
https://repositorio.uca.edu.ar/handle/123456789/9529 |
| identifier_str_mv |
0925-8574 10.1016/j.ecoleng.2018.09.013 Adrados, B. et al. Comparison of removal efficiency of pathogenic microbes in four types of wastewater treatment systems in Denmark [en línea]. Ecological Engineering. 2018, 124. doi:10.1016/j.ecoleng.2018.09.013 Disponible en: https://repositorio.uca.edu.ar/handle/123456789/9529 |
| dc.language.none.fl_str_mv |
eng |
| language |
eng |
| dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by-nc-sa/4.0/ |
| eu_rights_str_mv |
openAccess |
| rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-sa/4.0/ |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.publisher.none.fl_str_mv |
Elsevier |
| publisher.none.fl_str_mv |
Elsevier |
| dc.source.none.fl_str_mv |
Ecological Engineering. 2018, 124 reponame:Repositorio Institucional (UCA) instname:Pontificia Universidad Católica Argentina |
| reponame_str |
Repositorio Institucional (UCA) |
| collection |
Repositorio Institucional (UCA) |
| instname_str |
Pontificia Universidad Católica Argentina |
| repository.name.fl_str_mv |
Repositorio Institucional (UCA) - Pontificia Universidad Católica Argentina |
| repository.mail.fl_str_mv |
claudia_fernandez@uca.edu.ar |
| _version_ |
1877586709462384640 |
| score |
12.754232 |